42 Pin Replacement Cartridges for M8 PowerDerm 10X
$38.43
Pack of 10?42-pin Dr. Pen cartridges for M8 powerderm compatibility
- Crafted from premium stainless steel
- The 42-pin configuration is ideal for anti-aging, hair restoration, and improving skin texture
- A new cartridge should be utilized with each application
The Mechanism Behind Dr. Pen:
dr. Pen utilizes fine needles to create micro-injuries on the skin’s surface,triggering the body’s natural healing processes. This action promotes enhanced collagen and elastin production, leading to firmer skin while gradually diminishing scars and smoothing out wrinkles. The device can be maneuvered in multiple directions, making it suitable for various areas including the face, neck, décolletage, abdomen, thighs, buttocks, or scalp.
The Benefits of Using Dr. Pen:
- fast treatment duration
- Pinnacle precision during procedures
- Reliable performance outcomes
- Cable-free operation option available
- A built-in automatic depth control feature for injections
- Lesser discomfort and improved patient experience
- A reduced recovery period post-treatment
user Instructions:
- The cartridge is packaged in a sterile environment.
- Cleansing should involve a double-cleanse (cleanse twice) followed by an alcohol wipe to sanitize the area thoroughly. Ensure your hair is secured away from your face.
- Treat small sections at a time and apply serum before needling each area to prevent dragging on the skin’s surface. For optimal results, move the pen vertically first then horizontally followed by diagonal strokes in both directions using gentle pressure; repeat this technique over each section twice.
Please note: Detailed instructions are provided with your device including diagrams and tips for achieving maximum effectiveness. These guidelines can also be downloaded anytime via our help desk; our customer service team is always available to assist you with any inquiries.
How to Use (Educational) & Safety — Microneedling Cartridges
Important: Educational information only—not medical advice. Always follow your device manufacturer’s instructions and consult a qualified professional for treatment questions. Cartridges are compatible replacements, EO-sterilized, and single-use.
Before You Start
Check compatibility: Match the cartridge to your device model (e.g., M8/M8S/A6S/A11/A9/A20/H6). Connector/lock shapes are model-specific.
Inspect the pouch: Do not use if the sterile pouch is torn, punctured, or opened.
Hygiene: Wash/dry hands; prepare a clean workspace; avoid touching the needle array.
Single-use only: One cartridge per session, per person. Do not reuse or share.
Attaching the Cartridge
Power off the device.
Remove the cartridge from the pouch; avoid touching the tip.
Align the connector and click/lock per your device manual—do not force.
Confirm a secure fit (no wobble/misalignment) before powering on.
During Use (Follow Your Device Manual)
Use only as instructed by your device manufacturer.
If you notice unusual resistance, rough drag, or discomfort, stop and check fit/parts.
Do not use on irritated, broken, or compromised skin.
Keep the work area clean; do not place the tip on unclean surfaces.
After Use
Power off and detach the cartridge carefully.
Dispose of the used cartridge immediately as a sharps/contaminated item according to local rules.
Wipe the device head/handle as per the device manual; allow to dry.
Record or photograph the batch/lot code on the pouch for traceability.
Storage & Shelf Life
Store sealed pouches in a cool, dry place, away from heat, moisture, and direct sunlight.
Use before the marked expiry. Do not re-sterilize.
Warnings & Disclaimers
Single-use, sterile product. Reuse increases contamination risk and may degrade performance.
Use only with the correct model; cartridges are generally not interchangeable across series.
We are not affiliated with the original brand owners; names are for compatibility reference.
If irritation or unexpected reaction occurs, stop and seek professional guidance.
Common Mistakes to Avoid
Forcing a mismatched cartridge onto the device.
Touching or laying the needle array on surfaces before use.
Reusing a cartridge “to save costs.”
Using from a damaged or previously opened pouch.